Your English writing platform
Discover LudwigSuggestions(2)
Exact(1)
Decreasing contrast reduced both tuning width and response strength.
Similar(59)
Based on the findings on the "stress shell" and its mechanical properties, the 3D mechanical properties of the surrounding rock at LTCC faces were found, including the effect of mining height, the mechanism of pillar width and the response of advance rate.
An IRF, estimated by a Gaussian function, may account for excitation pulse width and detection response time by replacing F (Δ t | w 1 ) by F ¯ (Δ t | w 1 ) : Γ u) is the likelihood that the IRF delays any photon detection by a time u, θ[ u] denotes the step function (θ[ u > 0] = 1 and θ[ u < 0] = 0), and erf(x) denotes the error function.
No significant correlation was obtained between changes in tuning width and changes in response strength for low vs. high contrast and for low vs. medium contrast in the constant contrast condition as well (Fig. 10E and 10F, respectively) (low vs. high: Rho = −0.015, p = 0.9, 95% confidence interval: −0.32 to 0.29, low vs. medium: Rho = −0.082, p = 0.6, 95% confidence interval: −0.39 to 0.23).
A scan speed of 50 nm/min, 0.2 cm path length cuvette, band width of 1 nm and response time of 1 s were used.
The ellipticity was measured at 222 nm using 0.2 mg/ml protein in a 0.1 cm path length cuvette with band width of 1 nm and response time of 1 sec.
A reduced width and sharpening of responses at shorter stimulus duration was also found.
Along with the pavement temperature, it is well known that other parameters such as subsurface conditions (i.e. stiffness of base/subbase layers), setting temperature of concrete, slab dimensions, and joint/crack width also affect the behavior and response of JCP.
These clusters arise because of a combination of the differences between the power spectral densities of daylight and those of blackbodies, finite spectral sensor width and the noisy sensor responses.
(C ) Mitral cells display steady firing in response to brief light pulses (20 Hz, 10 ms pulse width) and (D ) enhanced firing in response to prolonged light pulse duration (20 Hz, 49 ms pulse width).
Shaded areas indicate the region for evaluating onset (starting from the peak of the voltage response, 100 ms width) and steady-state Rin (starting at the voltage response 1.75 s after the current injection, 250 ms width).
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com