Your English writing platform
Discover LudwigExact(13)
The 1981 Porton Trial Test 8 field study of the release of 40 m3 of a Freon-air mixture was used as a validation case to evaluate the behavior of volume integrated, cross-section integrated, depth integrated and full 3-d CFD models.
Treating two kinds of averages, which are generically called 'moments' and defined as the volume integrated average (VIA) and the surface integrated average (SIA) in this paper, as the prognostic variables makes the present method different from the conventional finite volume method where only VIA is the basic variable.
The presented method, namely VSIAM3 (Volume/Surface Integrated Average based Multi-Moment Method), employs two integrated moments which are called volume integrated average (VIA) and SIA (Surface Integrated Average), and results in a new finite volume formulation for solving general fluid dynamical problems.
Furthermore, due to the reduced mode volume, integrated optics has great potential to demonstrate strongly coupled cavity quantum electrodynamics [29].
Differently from conventional FVM where the volume integrated average (VIA) value is the only computational variable, the present formulation treats both VIA and the point value (PV) as the computational variables which are updated separately at each time step.
In addition to the volume integrated average (VIA moment) for each mesh cell, the point values (PV moment) defined on cell boundary are also treated as the model variables.
Similar(47)
For the match set containing images with pI 5-8, the spot volume (intensity integrated over the spot area) was normalized by the volume of total spots in the gel.
For the match set containing images from pI 5 8, the spot volume (intensity integrated over the spot area) was normalized to the total volume of spots in the gel.
MR-NMR spectroscopy can beneficially be applied for fast, non-invasive, and volume integrating analyses under rough environmental conditions.
After we obtained the binary blood flow pixel maps, the whole segmented binary map, which represents ONH volume, was integrated, the value of which was considered to be the percentage of blood perfusion volume compared to the whole ONH volume.
A suitable energy balance, where the fully heat transfer phenomena are considered, is established in an elementary volume and integrated along the kiln.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com