Sentence examples for use an echo planar from inspiring English sources

Suggestions(1)

Exact(1)

For this 2D DTI scan, we use an echo planar imaging (EPI) readout with gradients (b = 1000 s/mm) applied in 25 directions [ 22, 23].

Similar(59)

Functional images covering the whole brain were acquired axially using an echo planar imaging sequence (TR = 2000 ms, TE = 40 ms, flip angle = 80°, matrix = 64×64, FOV = 24×24cm; 4mm thickness and 0.5 mm gap, 23 slices).

Functional scans used an echo planar imaging sequence (TR=3 s; TE=35 ms; flip angle=90; voxel size=1.8×1.8×4 mm; 112 volumes).

In both cases, functional MRI images were acquired using an echo planar T2*-weighted gradient echo sequence (echo time = 51 ms, repetition time = 3000 ms, flip angle= 83°).

19 Task‐related BOLD signal changes were mapped using an echo planar imaging sequence (TR = 1,850 milliseconds, TE = 26 milliseconds, flip angle = 75°).

In brief, MRI data were acquired on a 3.0 Tesla GE Signa HDxt scanner (General Electric, Milwaukee, WI, USA) and fMRI data were acquired using an echo planar imaging T2* blood oxygen level dependent (BOLD) pulse-sequence.

Diffusion weighted images were obtained using an echo planar imaging sequence with 3 directions and 6 b-values (100/200/400/600/800/1,000 ms), TE = 53.47 ms, TR = 3,000 ms, 6 averages, acquisition time 8 min 24 s.

Forty-four transaxial gradient-echo images (echo time = 30 ms, flip angle = 85°, slice thickness = 2.5 mm, slice gap = 0.5 mm, FOV = 192 mm, matrix = 64 × 64, voxel size = 3 × 3 × 3 mm) covering the whole cerebrum were acquired during all sessions at a repetition time of 2.5 s, using an echo planar sequence and a Philips Achieva (3T) MR scanner.

The resting-state fMRI scans were performed using an echo planar imaging (EPI) sequence with scan parameters of repetition time = 2000 ms, echo time = 30 ms, flip angle = 90°, matrix = 64 × 64, field of view = 220 mm × 220 mm, and each volume comprised 33 slices with slice thickness = 5 mm without slice gap.

Resting-state fMRI scans were performed using an echo planar imaging (EPI) sequence with the following parameters: repetition time = 2,000 ms, echo time = 30 ms, flip angle = 90°, matrix = 64 × 64, field of view = 220 × 220 mm, slice thickness = 3 mm, and slice gap = 1 mm.

Functional data were acquired using an echo planar imaging sequence with a 90% flip angle and using generalized autocalibrating partially parallel acquisition (GRAPPA) with an acceleration factor of 2 in 31 near-axial interleaved slices (in-plane resolution 2.1 × 2.1, slice thickness 4 mm; distance factor 10%; field of view 200 mm) with TR = 2,000 ms and TE = 30 ms.

Show more...

Ludwig, your English writing platform

Write better and faster with AI suggestions while staying true to your unique style.

Student

Used by millions of students, scientific researchers, professional translators and editors from all over the world!

MitStanfordHarvardAustralian Nationa UniversityNanyangOxford

Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak quote

Justyna Jupowicz-Kozak

CEO of Professional Science Editing for Scientists @ prosciediting.com

Get started for free

Unlock your writing potential with Ludwig

Letters

Most frequent sentences: