Sentence examples for under voltage load from inspiring English sources

Exact(2)

This paper presents the design and implementation of a new method of under voltage load shedding in a power system incorporating the use of wind generators to maintain voltage stability following a severe disturbance.

Associated with the reclosing transients and motor starting inrush is the delayed voltage recovery effect, which further complicates the restoration process and may lead to under voltage load shedding [20, 52, 53].

Similar(58)

Under-voltage load shedding is the least and lowest cost solution to severe voltage problems [13].

Precisely, it can complete the under-frequency and under-voltage load shedding protection of the whole substation, strengthen the function of accurate load tripping based on traditional under-frequency and under-voltage load shedding protection, and realize comprehensive decision making with the combination of off-line strategy and on-line measurement information.

Meanwhile, it can realize automatic control functions, for instance backup power supply automatic switch-on (auto backup) of the whole substation, under-frequency and under-voltage load shedding protection, and breaker failure protection, etc.

Some under-voltage load-shedding strategies including real and reactive power load curtailments are adopted to mitigate system voltage instability [13, 14, 15, 16, 17, 18] in real-time operation of power systems.

Currently, the widely used load shedding methods mainly involve overall load shedding strategy [14] and under specific voltage load shedding strategy [15].

After performing load shedding for all influenced nodes, the under specific voltage load shedding strategy will be applied for remaining nodes.

For the previous example, the voltage variance after shedding load is used to evaluate the system stability, and the value when using the proposed strategy is only 10% of the value when using under specific voltage load shedding strategy.

For example, regarding the obtained failure chain l 1, l 14, l 44, l 26, l 6, l 7 and l 8 in IEEE-39 test system, if using under specific voltage load shedding strategy, the load losses will be 1138.2 MW, while when using the proposed load shedding strategy, the load losses are only 446.5 MW.

Examples of SIPS include [55]: generator rejection, load rejection, under frequency and voltage load shedding, system separation, dynamic braking, and turbine valve control.

Show more...

Ludwig, your English writing platform

Write better and faster with AI suggestions while staying true to your unique style.

Student

Used by millions of students, scientific researchers, professional translators and editors from all over the world!

MitStanfordHarvardAustralian Nationa UniversityNanyangOxford

Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak quote

Justyna Jupowicz-Kozak

CEO of Professional Science Editing for Scientists @ prosciediting.com

Get started for free

Unlock your writing potential with Ludwig

Letters

Most frequent sentences: