Exact(4)
Drying shrinkage, capillary water absorption and water tightness tests were performed to characterize the physical properties of the composites.
The paper concludes with a description of the required pre-qualification tests performed to SHOBU, i.e. pressure and leak tightness tests, according to the standards.
Furthermore, air tightness tests show that, due to poorly sealed joints between construction elements, windows and doors, many buildings have high infiltration rates, reaching up to 5 air changes per hour.
The main FMUs characterization results are reported (e.g. pressure resistance and helium leak tightness tests, mechanical properties and microstructure at the weld joints, geometrical characteristics of the sub-components and internal cooling channels) and the key pF/WPS steps and parameters are outlined.
Similar(56)
The component installations and the pneumatic and tightness test are also described, including the objectives and methods.
A gas tightness test has been carried out at 800 °C for 1100 h in dual atmosphere (Ar-H2 and air) without recording any leakage.
This entails scantling plans inspection, types of material, types of welded joints, water-tightness tests, freeboard markings, electrical systems, fire prevention detection and extinction requirements, pumping and piping systems, boilers and other pressure vessels, refrigerated cargo installations, annual and special surveys, carriage of engineering spares, machinery, and propulsion units.
After the module was constructed, gas-tightness tests were carried out using helium and the measured helium leakage was 8 × 10−5 mol m−2 s−1 at 0.7 MPa, which is the same as the value detected before diffusion bonding with a Viton O-ring.
Air-tightness test indicated a test chamber relief rate of 26 Pa/min, which meets the design requirements.
Each of the submitted instruments was subjected to a seal-tightness test to determine their fundamental functionality.
In the first part of the paper, the new approach is tested through a database of 406 room temperature tightness (ROTT) tests performed on different gasket styles.