Exact(1)
The circular dichroism signal was monitored by a JASCO J-810 CD spectrometer (JASCO inc., Easton, MD) equipped with a Peltier thermoelectric controller.
Similar(59)
A thermoelectric temperature controller controls the device temperature during measurements.
A thermoelectric temperature controller was used to regulate and monitor the device temperature during measurements.
Particle size distribution and electrokinetic potential of uncoated and lipid-coated SPIONs were determined by dynamic laser light scattering (DLS) using the Zetasizer Nano-ZS (Malvern Instruments, Worcestershire, UK) equipped with a 4-mW helium/neon laser (λ = 633 nm) and a thermoelectric temperature controller.
Circular dichroism spectra were collected on a Jasco J810 (Japan) spectropolarimeter equipped with a Peltier thermoelectric temperature controller.
The fluorescence spectra were collected at 25°C on a Cary Varian spectrofluorimeter (Varian, USA), equipped with a Peltier thermoelectric temperature controller.
CD spectra from 215 to 240 nm were measured in a J810 (Jasco, Easton, MD) spectropolarimeter equipped with a 150W xenon lamp and a PFD-425S thermoelectric temperature controller (Jasco, Easton, MD).
CD spectra (185 260 nm) were also made for Mini-B in 4∶6 v∶v TFE:10 mM phosphate buffer (pH 7.4) using a JASCO 715 spectropolarimeter (Jasco Inc., Easton, MD) fitted with a thermoelectric temperature controller and calibrated for wavelength and optical rotation using -10-camphorsulphonic acid [64].
DLS experiments were performed with a Zetasizer Nano instrument (Malvern Instruments Ltd., United Kingdom) equipped with a 10 mW helium neon laser (λ = 632.8 nm) and a thermoelectric temperature controller.
CD spectra were recorded using a Jasco J-815 spectropolarimeter equipped with thermoelectric temperature controllers (Jasco Inc .. Far-UV (193 250 nm, 1 nm bandwidth) data were collected using a 1.0 mm path length quartz cell, smoothed with the Jasco noise reduction routine, normalized to protein concentration, and presented as mean residue molar ellipticity (MRE) for individual proteins.
Dynamic light scattering (DLS) was performed with a high performance particle sizer (Malvern Instruments) equipped with an He Ne laser (633 nm) and a thermoelectric Peltier temperature controller (temperature control range 10 90 °C).
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com