Sentence examples for system suitability for from inspiring English sources

Exact(1)

To provide a more constructive explanation of outcome and explanatory variables, we caution that the use of indicators, to judge performance of insurance schemes related to ORU, requires a clear understanding of the organizational structure, operational arrangements of the system, suitability for purpose and context, and caveats about interpretation.

Similar(59)

Table 1 System suitability parameters for TAP Parameters Value for TAP a SD %RSD Number of theoretical plates 21,930 61.64 0.281 Tailing factor 1.12 0.051 0.956 Capacity factor 16.44 0.222 1.352 RT (min) 5.34 0.037 0.698 Peak purity 1.00 0.000 0.000 RT retention time, SD standard deviation, %RSD percentage of relative standard deviation.

System suitability values for the method were derived from the regression surface analysis.

Capillaries were slurry packed with 5 μm 100-Å porous silica particles modified with teicoplanin and initially evaluated using a non-aqueous polar organic mode system suitability test for the separation of metoprolol enantiomers (Rs=2.3 and 53 000 plates m−1).

The development of an ion-pairing HPLC method and associated system suitability parameters for the analysis of atomoxetine hydrochloride (LY139603 HCl) using a quality by design approach is described.

Acceptable system suitability results for a chromatographic run establish that the method is performing adequately and can be used to generate reportable data.

Resolution condition of not less than 2.0 between lafutidine and related compound D was set as system suitability parameter for SSM.

Table 1 System suitability parameters for OLO in 0.1% formic acid and methanol (35:65) on C18 column Parameters Value (n= 6) SD %RSD Number of theoretical plates 8,578 42.63 1.09 Tailing factor 1.31 0.94 0.49 RT (min) 3.77 0.046 0.021 Peak purity 1 0 0 SD standard deviation, RSD relative standard deviation, RT retention time.

Furthermore, the insignificance intervals for significant factors were calculated and the parameters for system suitability tests were defined.

Firstly, the column test performance based on the LC separation of the samples containing lamotrigine for system suitability CRS which had been prepared as described in Section " Column performance for the determination of lamotrigine: Materials," and analyzed in the chromatographic conditions presented in Section " Equipment and LC condition," was carried out on HYB column.

Resolution (Rs), theoretical plates number (N) and tailing factor (T) were measured as the criteria for system suitability testing.

Show more...

Ludwig, your English writing platform

Write better and faster with AI suggestions while staying true to your unique style.

Student

Used by millions of students, scientific researchers, professional translators and editors from all over the world!

MitStanfordHarvardAustralian Nationa UniversityNanyangOxford

Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak quote

Justyna Jupowicz-Kozak

CEO of Professional Science Editing for Scientists @ prosciediting.com

Get started for free

Unlock your writing potential with Ludwig

Letters

Most frequent sentences: