Similar(60)
The results of the study have shown that both the wave height and the crest height distributions are primarily dependent upon the effective water depth (kpd), where kp is the wave number corresponding to the spectral peak and d the water depth, and the sea state steepness (1/2Hskp), where Hs is the significant wave height.
The experimental results show that the weakly three-dimensional experiments have little influence on the profile of wave trains with relatively low initial steepness (0S= 0.215.
The metrics of squared Laplace image (3 ms), Mendelsohn and Mayall (3 ms), Riemann tensor (5 ms), steepness (8 ms) and maximal gradients (13 ms) have been tested.
The models predict the relative scour depth (Smax/H0) on the basis of the following variables: relative water depth at the toe of the breakwater (htoe/L0), Shields parameter, non-breaking wave steepness (H0/L0), and reflection coefficient (Cr).
A beam splitter (BS) reflects the modulated light which is focused by a lens (L) to a CCD camera Table 1 Sharpness metric calculation time for a single image Metric Type Calculation time S1 Squared Laplace image 3 ms S2 Mendelsohn and Mayall 3 ms S3 Riemann tensor 5 ms S4 Steepness 8 ms S5 Maximal gradients 13 ms.
The result shows that the equilibrium shorelines depend not only on the breakwater length B and the distance of the breakwater from the initial shoreline S, but also on the incident wave steepness H0/L0, beach slope Sb and the sand size D50.
Thus, for further experiments we were choosing slope steepness 0.25, which seems a good compromise.
The use of ϕF values can also provide useful insights, although interpretations may be complicated by changes in harmonic profile steepness (6).
An inverse relationship was found between gap length and slope at threshold, with a stimulus-dependent main effect on psychometric function steepness observed, F 3, 390) = 4.59; p =.004.
Fig. 6 Results generated by Matlab's ode15s solver, with steepness parameter (beta=150) and (T=0.2).
In patients with chronic pain, pain relief was related to the R, S-methadone concentrations by a sigmoid E max model defined with an EC50 of 290 ng/ml and a steepness of 2.03 [ 25].
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com