Suggestions(1)
Exact(6)
The spectrum scales from using verbal force to firing a gun.
i.e. for discontinuous velocity fields, the real part of the spectrum scales as 1 / N 2, while the imaginary part is of even higher order.
Our analysis has revealed that, for discontinuous velocity fields, the spectrum scales as 1 / N 2 and the stability is controlled by the sign of the difference between the velocity at reset and at threshold.
We find that in the case of discontinuous velocity fields, the Floquet spectrum scales as 1 / N 2 and the stability is determined by the sign of the jump at the discontinuity.
By developing an approach that is valid for arbitrary coupling strength and is perturbative in the inverse system-size 1 / N, here we prove that the Floquet spectrum scales as 1 / N 2 and is proportional to F ( 1 ) − F ( 0 ).
The running time for Riptide to score a given spectrum scales approximately as O lN p N i log(N s )), where l is the average length of a peptide, N p is the number of candidate peptides for that spectrum, N i is the number of ion series under consideration, and N s is the number of peaks in the particular spectrum.
Similar(54)
We correct for the saturation effect on mb − Mw measures using the ω-squared source spectrum scaling of Brune (1970).
Existing suites of ground motion time histories were scaled using linear response spectrum scaling for soil conditions using a well-known attenuation relationship.
However, results obtained by the Roe solver agree well with the theoretical energy spectrum scaling providing a marginal dissipation without showing any pile-up at a cost of around 30% increase in computational time.
This is given by the Eurocode 8 elastic response spectrum, scaled at a given peak ground acceleration and account for the position of the sub-service within the building.
The event selection process and mb − Mw differentials, corrected for source spectrum scaling over the full range of Mw (5.0 to 9.0) for the subduction zone near the 2011 Tohoku earthquake are illustrated in Fig. 2. The gCMT best double couple focal mechanisms are plotted at the gCMT centroid locations with colors indicating the centroid depth and symbol sizes scaled proportional to Mw.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com