Your English writing platform
Discover LudwigSuggestions(1)
Exact(1)
Embryos at stage 14 were incubated in 100 μl 0.4 M lithium chloride (Roth) solution for 10 minutes at 27°C, followed by electroporation using the following settings: modulation frequency 330 Hz; voltage 15 V; pulse time 100 ms; 1 pulse.
Similar(59)
Typical spectrometer settings were modulation frequency, 100 kHz; modulation amplitude not more than one-third of the peak-to-peak linewidth, and scan range, 2 mT.
Typical spectrometer settings were: modulation frequency, 100 KHz; modulation amplitude not more than one-third of the peak-to-peak line-width, and scan range, 2 mT.
In consideration that inflammatory cytokines are qualified to induce inflammatory settings by modulation of miRNAs, our findings are concordant with these results [ 31, 32].
On the other hand, thermal conductivity can be obtained in the steady-state measurement by adjusting modulation settings.
The effects of chloroquine are, however, not limited to autophagy inhibition, causing, among other things, inhibition of lysosomal function in general, and it is important to note that in vivo genetic verification that the effects of chloroquine in these settings was through modulation of autophagy is yet to be established.
Table 1 Simulation settings Three-carrier Signal Modulation format 8 PSK, 16/32 APSK Symbol rate (T r ) 7 M Baud Carrier Spacing 1.25 T r Coding scheme LDPC (frac {3}{4}, frac {4}{5}, frac {5}{6}, frac {8}{9}, frac {9}{10}) Channel Pulse-shaping filter SRRC ρ=0.25 IMUX bandwidth 26 MHz OMUXUX bandwidth 32 MHz Simulation rate 20 HPA Saleh's model.
Neri et al managed to perform successful CTC examinations for CRC screening purposes with an even lower radiation dose (2.2 mSv) by using a combination of low exposure settings and tube current modulation.
The Varian E-6 EPR spectrometer was used for the measurements with the following settings: frequency of 9.225 GHz, modulation amplitude of 2 G, modulation frequency of 100 kHz, scan time of 4 min, power of 20 mW, and temperature of 23 °C.
We observed that by slightly modulating the ultrasound frequency (typical settings: 20 kHz frequency deviation, modulation frequency 1 kHz), we are able to significantly suppress unwanted horizontal confinement due to an averaging effect over several different standing wave patterns.
Spectrometer settings were the following: magnetic field modulation of 0.1 mT, modulation of frequency of 100 kHz, microwave power of 10 mW and microwave frequency of 9.15 GHz.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com