Your English writing platform
Discover LudwigExact(4)
The Swarm accelerometers are claimed to have the same performance for all three axes, opposed to the CHAMP and GRACE accelerometers, which have two very sensitive axes and one relatively less sensitive axis.
The drag-free and attitude control system (DFACS) is monitored by the common-mode data of the accelerometers along their three axes, while the possible violation signal is detected by the differential-mode data along the longitudinal sensitive axis.
During the scientific measurements, two test masses on board of the spacecraft are put into a pure gravitational free fall around the sensitive axis with an accuracy of about 3x10-14 m/s2√Hz in the measurement bandwidth between 1 mHz and 30 mHz.
To evaluate the technical performance of the nine RT3 accelerometers in this study for field use, each monitor was subjected to specific vibration testing along each sensitive axis in isolation.
Similar(56)
This paper deals with the method of alternating sensitive-axis field biasing and its influence on the sensor properties.
The concentrations of O2 a1Δg) and O3 were measured quantitatively through absorption by sensitive off-axis integrated-cavity-output spectroscopy and one-pass line-of-sight absorption, respectively.
This process was associated with increased CCL4 levels and was partially dependent on a pertussis toxin (PT -sensitive recePT -sensitive
Hypertriglyceridemia was accompanied by an increased expression of tissue, and plasma CCL4 and blood Gr1low monocyte depletion involved a pertussis-toxin-sensitive receptor axis.
Also, sensible placement of resin inlets and outlets could reduce the amount of deleterious voids, i.e. by promoting resin flow along the fibre direction in the most defect-sensitive off-axis layers.
This paper presents a novel X Y dual axis sensitive sensor for static electric field measurement.
The testing comparison of the microswitches with and without constraint structure indicates that the contact-bouncing behavior is easier to happen if without constraint structure, which indicates that the designed constraint structure can restrain the vibration of the proof mass in z-off-axis sensitive direction and effectively improve the stability of the device.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com