Exact(6)
When selecting an MS, a variety of important factors should be considered such as the m/ z range to scan, sensitivity, resolution, vacuum system, and gas supply.
CopasiWeb [ 49] provides stochastic and deterministic time course simulation (steady state, time course, metabolic control analysis, parameter scan, sensitivity analysis, parameter estimation).
CT scan sensitivity and specificity are claimed to be 95% but this high percentage can only be reached in clinically high suspected VPGI [ 7– 9].
Since there was no 99mTc-pertechnetate outside the phantom, the increase in scan sensitivity can be estimated by comparing the total number of detected photons obtained using each of the FOV selection protocols.
For monkey M1 and M2, we increased the scan sensitivity by using a gradient insert coil (Siemens AC88) with a gradient echo EPI sequence (TR 1400 ms, TE 10 ms, 1.25 mm isotropic voxels, and 40 slices).
The reported data on PET scan sensitivity represent preliminary results but the clinical role of PET in lung metastases will be further studied and described in a separate analysis.
Similar(54)
This treatment resulted in a adequate contact angle, producing a nano-textured surface with potential features for a good attachment and orientation of deposited bio-molecules, and a very low background fluorescence, hence allowing a high degree of scanning sensitivity, for application on DNA microarrays.
But since the same modifications can also be applied to the corresponding phase-cycled correlation experiments, 17 the MQD gain in per-scan sensitivity, as outlined below, can also be applied to these sensitivity improved experiments.
The concept is generally applicable to all indirect evolution dimensions of N-dimensional pulsed NMR spectra and offers a time reduction of (3/4) N −1 compared to conventional spectra, while retaining resolution, axial peak suppression, and per-scan sensitivity.
A number of scans smaller than this is only possible, when compromising either the per-scan sensitivity (e.g. by gradients during evolution) or coherence selectivity (e.g. by omitting axial peak suppression).
A curve representing the long range A-Scan sensitivity was calculated as a sum of fitted curves for the single A-scan sensitivities. Figure 5 shows that the sensitivity of each individual channel drops by more than 6 dB for an OPD = 2 mm away from the maximum, giving less than 4 mm usable range for a single channel.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com