Your English writing platform
Discover LudwigSuggestions(1)
Similar(60)
Both elastic and inelastic analyses are performed on all scales for various CNT weight fractions, defining a different nonlinear constitutive stress strain behavior at each scale of separation.
As the dimensions of the CNTs and those of a typical mesoscale concrete RVE differ by orders of magnitude, a hierarchical multiscale analysis strategy is implemented to pass information through scales with different RVEs assigned at each scale of separation.
To lower the limit of quantitation for PAHs, the scale of separation process was increased using a preparative SEC column (dc = 25 mm, Lc = 250 mm, dp = 10 μm).
The use of the capillary and/or electrophoretic force decrease the size and time-scale of separations.
The multiple examples of unexplained pulses on just one or two of the six sensors deployed demonstrated the need for multiple scales of separation of different recording stations, in order to be able to separate individual sensor noise from multi-component system noise, local cultural noise, possible tectonic signals, and/or regional geomagnetic noise.
In this paper, our purpose is focused on the study of the mass transfer kinetics and equilibrium of the separation of glycine and ammonium chloride, in order to apply this technology to an industrial scale for separation of glycine from salts by SMB chromatography.
With hollow fibers the volume scale of the separation can be downscaled and the instrumental complexity reduced, and possibilities are foreseen to develop "disposable" separation channels for, e.g., clinical use.
This selection is also affected by the scale of the separation process, economical considerations, questions of environmental safety, and many others.
The length scale of phase separation was manipulated by controlling the ratio of short chain to long chain propylene oxide diamines.
Here, we introduce an Orbitrap for GC applications, the GC/Quadrupole-Orbitrap, which substantially improves upon the proof-of-principle system: using a benchtop Orbitrap LC/MS as the base platform, we have developed an applications-grade GC/MS that not only enables high mass accuracy and high resolution analysis, but does so at scan rates amenable to the time-scale of GC separations.
Ion mobility (IM) separation is on the millisecond time scale, nesting within the time scale of nano-LC separation (seconds) and TOF-MS acquisition (∼100 μs), allowing multiple mass spectra to be taken of each ion mobility separation and providing an additional degree of peak capacity.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com