Your English writing platform
Discover LudwigSuggestions(1)
Exact(1)
\scriptstyle Z_0 also varies with frequency and is also partly reactive; both these features will be the cause of reflections from a resistive line termination.
Similar(59)
Due to mismatched resistive and inductive line impedance, power sharing and output voltage of the parallel DG inverters deviate from the reference value.
a DC link voltage of H-bridge 1. b DC link voltage of H-bridge 2. c DC link voltage of H-bridge 3. d AC output voltages of three H-bridges feeding resistive load blue (line current) Open image in new window Fig. 11 Performance of the proposed system under different DC input voltages.
This observed behavior diminishes as the resistive component of lining impedance is increased.
The method begins with the feature extraction of ZnO arresters by using on-line resistive current monitoring and infrared radiation (IR) image inspection.
In Figs. 21b, 22a, we show a white line bounding resistive crystalline rock from less resistive sedimentary rock to the east.
As accurate and efficient timing prediction is very important for integrated circuit design, an analytical timing model for inductive-effect dominated resistance inductance capacitance (RLC) transmission line with resistive driver and capacitive load is proposed by virtue of traveling wave propagation and perturbation technique.
For the current shared problem of multi inverters connected the grid in the micro-grid, the virtual reactance is introduced to solve the strong coupled problem between active power and reactive power when the line shows resistive characteristic, so the distribution of power among inverters can be achieved by conventional power droop control.
For the application in the EHV transmission line, the resistive type has to deal with several difficult problems such as high voltages at cryogenic temperatures to ensure a reliable electrical insulation, recovery time after quench to meet the requirements of the circuit breaker reclosing system.
Long, narrow interconnect lines increase the resistive and possibly inductive characteristics of a line, requiring unique design methodologies to enhance system performance.
Utilizing the designed VSC-HVDC systems, the feasible locations of resistive SFCLs were evaluated when DC line-to-line, DC line-to-ground and three phase AC faults were occurred.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com