Your English writing platform
Discover LudwigExact(23)
Under optimal conditions, VALLME-SFO was validated in terms of limit of detection, limit of quantification, dynamic linearity range, determination of coefficient, enrichment factor and extraction recovery for which the respective values were (0.011 0.219 ng mL−1), (0.035 0.723 ng mL−1), (0.050 0.500 ng mL−1), (R2 = 0.992 0.999), (40 56), (80 106%).
However, when the DLLME-SFO method was validated under optimal conditions, the range of values of limit of detection, limit of quantification, dynamic linearity range, determination of coefficient, enrichment factor and extraction recovery were (0.025 0.377 ng mL−1), (0.083 1.256 ng mL−1), (0.100 1.000 ng mL−1), (R2 = 0.990 0.999), (35 49), (69 98%) respectively.
If the forecast range determination, presented in Section 2.4, is accurate, the set of the recorded values and the S-curve, modeled according to them, should be situated within or nearby the forecast's range in Fig. B1.
Following these exclusions, 862 samples were included for clinical reference range determination.
Our data collection method was in accordance with the rigorous CLSI guidelines for determining laboratory reference ranges, which recommends a minimum of 153 subjects for a 95th percentile clinical reference range determination with 95% confidence [17].
Although the number of females was disproportionate to males (20% vs. 80%) in this study, the number of females included in reference range determination for each analyte was well within the guidelines of CLSI of 120 subjects[8].
Similar(37)
These position descriptions outline characteristic elements of job content and minimum educational and experience levels, and are used as common reference points to ensure that consistent and fair range determinations are made with respect to specific Support Staff positions at the Institute.
Also, the number of women with availability of total hCG measurements varied for each gestational week and therefore reference range determinations were not equally reliable throughout gestation, particularly during very early and the third trimester of pregnancy.
Our host-range determination study demonstrated that this phage was incapable of cross-infecting with other genera or species of LAB tested.
The MFCs supermicro-crystal structures have shown synergistic enhancement in selective sensing assay associated with low-detection limit up to part-per-billion (ppb), wide-range determination (0.5 ppb to 2000 ppb) and fast response monitoring in the order of second during the binding of Zn2+ ion target.
These genome sequences may provide a good opportunity to study bacterial evolution and identify the genes contributing to host-range determination.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com