Your English writing platform
Discover LudwigExact(4)
The trials are using Masimo SET Radical pulse oximeters (Masimo, Irvine, California, USA).
We have shown that when it is used to monitor preterm infants receiving supplemental oxygen, the Masimo SET Radical pulse oximeter returns a reduced number of values of 87 90%.
A characteristic of the software algorithm reduces the frequency of saturations of 87 90% and increases the frequency of higher values returned by the Masimo SET Radical pulse oximeter.
The baby also had an unmodified Masimo SET Radical pulse oximeter attached, and the two simultaneous saturation profiles show the reduced number of values of 87 90% in the Masimo histogram and the higher number of SpO2 readings of 91 96% that were obtained with the Masimo oximeter.
Similar(56)
To our knowledge, this is the first study to present reference ranges recorded using a Masimo Radical pulse-oximeter with 2 s averaging in a prospective cohort of healthy term infants from 2 weeks to 24 months.
The Masimo Radical pulse-oximeter was generally effective in identifying artefact (82.5%, 66.3%, 80.1%, 93.3% and 90.0% of total manually scored artefacts in infants at 2 weeks, 3, 6, 12 and 24 months, respectively).
In conclusion, this paper presents reference ranges for healthy term infants aged from 2 weeks to 24 months of nocturnal SpO2 recordings using a Masimo Radical pulse-oximeter with 2 s averaging.
This study compared 3 POC testing devices the Radical-7 pulse oximeter (Radical-7, Neuchȃtel, Switzerland), the i-STAT (Abbott Point of Care, Princeton, NJ), and the GEM 4000 (Instrumentation Laboratory, Bedford, MA)—to the hospital reference device, the UniCel DxH 800 (Beckman Coulter, Brea, CA) in cardiac surgery patients.
Information about Masimo RADICAL-7 pulse oximeters and Philips IntelliVue MP70 multimeasurement monitors was collected (see Table 2).
Patients wore Rainbow adult resposable sensors (R2-25, REvision E) connected to a Radical-7 Pulse CO-Oximeter, software version 7.6.0.1.
Hemoglobin values reported from the invasive methods were compared with the values reported by the Masimo Radical-7 Pulse CO-Oximeter at the time of the blood draw.