Your English writing platform
Discover LudwigSuggestions(1)
Exact(2)
The syngas produced contains below 500 ppm of methane.
The staircase response to methane indicated a 44 mV sensor response to 100 ppm of methane.
Similar(58)
Benefiting from the high RI sensitivity and high quality factor of the microcavity, a theoretical detection limit of 697.35 ppm for methane sensing can be achieved.
Fructose malabsorption is identified by a positive breath test, which is most commonly defined as a rise in hydrogen and/or methane (methane is less frequently measured) of at least 20 ppm (less often 10 ppm for methane) peaking from 1.5 to 3 hours after ingestion of the test carbohydrate.
1H NMR analyses confirmed that the oxirane ring (–CH O CH–) of MEOA at 2.92 3.12 ppm and four signals of methane (–CHCH–) was at 5.38 5.49 ppm while the 13C NMR showed the oxirane ring (–C O C–) at 54.59 57.29 ppm and the olefinic carbons at 124.02 132.89 ppm.
Gas contents increase to 72.13 ppm for methane and to 11.12 ppm for ethane, both at 1,069-m 1,069-m
The contents of each bag were recorded as ppm of the total methane test gas collected, and these were compared to a target ppm value for the dilutions used.
Gas chromatography (Model DP; QuinTron Instrument Company, Milwaukee, Wisconsin) was employed to measure the concentration in parts per million (ppm) of hydrogen and methane in the air.
In this work, the implementation of a new methodology to design and simulate an industrial scale pressure and temperature swing adsorption process at low temperature (Cryo-PTSA) is presented, in order to produce an almost pure methane stream, with a maximum of 50 ppm of CO2, maximizing the methane recovery.
Different values of gas surface velocity (0.1 0.3 m/s), particle diameter (3 6 mm, for particle bed), cell density (200 400 cpsi, for structured bed) and catalyst/inert ratio (0.4 1) were used for the simulation of the combustion of 3500 ppm methane in both kinds of reverse flow reactor.
We observed more variation about the higher dilution of 1 500, target value of 200 ppm methane gas, when compared to the lower dilution of 1 193, target value of 520 ppm methane gas; this was primarily because the syringe sensors were adjusted at the latter dilution.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com