Your English writing platform
Free sign upSuggestions(1)
Exact(1)
However, Nakajima et al. have recently shown that standardization of H/M ratios by a heart chest calibration phantom method is feasible among different collimator types, allowing practical multicentre comparisons of H/M ratios [ 27].
Similar(59)
Table 2 Scanning protocols and assumed brain activity at scan start that are used to derive the phantom methods of Table 1 PET drug Standard injection activity Accumulation time Standard scan time Estimated brain activity at start of scan FDG 185 MBq 30 min 30 min 20 MBq PiB 555 MBq 50 min 20 min 3 MBq Florbetapir 370 MBq 50 min 20 min 12 MBq Flutemetamol 185 MBq 90 min 30 min 3 MBq.
Various studies demonstrated techniques to minimize these artifacts; Kuo et al. (2010) examined an in-phantom method using inversion recovery with ON-resonant suppression (IRON) to generate positive contrast in areas of high magnetic susceptibility artifact (Kuo et al. 2010).
The DXA device was calibrated daily and weekly by using appropriated phantoms methods.
In the current study, the traditional phantom node method is extended for crack propagation modeling of composite materials under fatigue loading.
The presented fatigue phantom node method is coded as an user-defined element in ABAQUS and its numerical implementation, including global data, element connectivity and, especially, a pre-cracking treatment, has been discussed in detail in consideration of limitations from the commercial FE software.
When the phantom replacement method was used, the calculated concentrations were strongly dependent on coil loading conditions.
We compared these results to parallel estimates of concentrations obtained using the more established phantom replacement method.
In contrast, the concentrations determined using the phantom replacement method are highly dependent on coil loading conditions.
When the surface coil was overloaded during the calibration session, the phantom replacement method consistently overestimated the metabolite concentrations by about 10%.
In contrast, the concentrations determined with the phantom replacement method were clearly erroneous when in vivo coil loading conditions were not properly replicated during the calibration session.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.
Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com