Your English writing platform
Discover LudwigExact(23)
Studies with surface sensitive equipment such as XPS and TOF-SIMS demonstrate enough chemical heterogeneities throughout the surface of commercial stents to assure that proteins dispersed in blood would not have equal interaction from point to point on the device surface [ 27].
Atomic force microscopy measurements show that when in situ annealing of QDs without AlAs capping layers is investigated, holes and dashes are present on the device surface, while capping with one monolayer AlAs improves the device surface.
The first step is the anti-M13 (Amonoclonallonantibodyody grafting, on the device surface (SiO2).
In addition, poly(HEMA) coated with poly ethylene oxide)/poly(propylene oxide)/poly ethylene oxide) (PEO PPO PEO) surfactant was utilized to enhance mucoadhesion on the device surface.
This study aims to understand of characters of concentrated sun rays through KIER solar furnace and design of device shape for uniform heat distribution on the device surface.
Based on this engineering background, we consider an inverse problem for 1-dimensional heat conduction model, with the aim of detecting the nonsmooth heat dissipation coefficient from measurable temperature on the device surface.
Similar(37)
In the LPE effect, a lateral photovoltage (LPV) can be obtained and it changes linearly with the laser spot position on the active region of the device surface.
The developed drug-loaded MNPs could be injected in the patient soon after device implantation to prevent biofilm formation, or, later, in presence of signs of infection to treat the biofilm grown on the device surfaces.
We report on our experience in the control of magnetron sputtering process by in-situ monitoring of a surface acoustic wave (SAW) device (resonator or delay line) electrical response during the deposition of dielectric layers on the SAW device surface.
For a given antigen concentration, the rate of fluorescence production increased with the number of specimen loads, indicating immunocomplexes were being enriched on the microfluidic device surface.
To facilitate cell capture on the implanted device surface using physiological flow-mediated mechanisms, tubes with lumenal surfaces adsorbed with P-selectin were incorporated into blood circulation via insertion into the femoral artery of anesthetized rats.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak