Sentence examples for mode scan of from inspiring English sources

Exact(2)

Three-dimensional images of rough and smooth implant surfaces were obtained by means of atomic force microscopy (AFM) using the tapping mode scan of an AFM VEECO machine (Plainview, USA); this method was also used to determine the surface topography.

With the radius of the NW r being deducted from the taping mode scan of the NW, a linear fit of k wire -1/3, as a function of the forcing location a, allows the calculation of E. Si NW grown along the (111) direction have been tested (results not shown).

Similar(58)

The intensity profiles obtained after averaging of 2D contact mode scans of the imprinted virgin glass and GMN sample along the strips are shown in Figure 3.

Collision energy was set to 15V and product ions of IAA and IBA were targeted with positive mode scans of m/z 50 200.

With availability of enhanced depth-imaging mode, scanning of the choroid is now feasible.

Open image in new window Fig. 12 Transverse B-mode scan of the penis of a 36-year-old man (a) shows enlargement of the right corpus cavernosum penis, as well as an indistinct hypoechoic area (arrow) in its centre.

Figure 3 shows sonographic images before and immediately after injection in a paramedian, sagittal B-mode scan of the upper lip.

Based on our SD mapping approach, there is a certain D value in an A-mode scan of a normal sample (see Fig. 9(c)) even though no dysplastic cell distribution exists.

In other words, D is regarded as the range percentage of dysplastic cell distribution in the whole EP layer along an A-mode scan of a MiD or MoD sample.

By using high-resolution ultrasound with a 15-MHz linear array transducer (VIVID E9; General Electric), we obtained an optimal longitudinal B-mode scan of the brachial artery (∼5 cm above the elbow crease) with the probe held by a stereotactic clamp to ensure steady image recordings.

B-mode scan of the right brachial artery, in a longitudinal section 2 to 12 cm proximal to the antecubital fossa, was performed in supine participants using a vascular software for two-dimensional imaging, color and spectral Doppler, an internal electrocardiogram (EKG) monitor, and a 7.5-MHz phased-array transducer Hewlett-Packard SONOS 5500 system (Hewlett-Packard, Palo Alto, CA, USA).

Show more...

Ludwig, your English writing platform

Write better and faster with AI suggestions while staying true to your unique style.

Student

Used by millions of students, scientific researchers, professional translators and editors from all over the world!

MitStanfordHarvardAustralian Nationa UniversityNanyangOxford

Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak quote

Justyna Jupowicz-Kozak

CEO of Professional Science Editing for Scientists @ prosciediting.com

Get started for free

Unlock your writing potential with Ludwig

Letters

Most frequent sentences: