Your English writing platform
Discover LudwigExact(9)
The mobile phase comprised of acetonitrile/water with a gradient system as follows: 0 min.
Separation was achieved using a Phenomenex® Luna 5 μm (C18) column and a mobile phase comprised of phosphate buffer (adjusted to pH 3.0): acetonitrile in a ratio of 70 30 (v/v).
High performance liquid chromatography (HPLC) separation was conducted on an YMC ODS-AQ C(18) column with a flow rate of 0.3 mL/min using a mobile phase comprised of 5 mM ammonium acetate buffer/0.03% formic acid in the solvent mixture of methanol/acetonitrile/water (20 20 60, v/v/v).
The mobile phase comprised of A: methanol-10 mM KH2PO4-triethylamine in a ratio of 96:6:0.01 (v/v/v) and B: methanol.
The mobile phase comprised of acetonitrile (40%) and water containing 0.1% w/v triethylamine with pH adjusted to 3 with ortho-phosphoric acid (60%).
The HPLC mobile phase comprised of acetonitrile buffer (20∶80, v/v, buffer 50 mM KH2PO4, pH of 6.8 adjusted with KOH).
Similar(51)
The mobile phases comprised of 100%% water in 5 mM ammonium formate containing 0.1%% formic acid for solvent A and acetonitrile in 5 mM ammonium formate containing 0.1%% formic acid for solvent B. A gradient elution at a flow rate of 0.4 mL/min was used.
The HPLC-PDA method was utilized for simultaneous determination of the chlorogenic acid, caffeic acid, hyperoside, isoquercitrin, isochlorogenic acid A and scoparone content of A. capillaris using mobile phases comprised of 1.0% (v/v) acetic acid in water (A) and 1.0% (v/v) acetic acid in acetonitrile (B).
The peptides were separated using the mobile phase comprising of solvent A (0.1% formic acid in water) and solvent B (0.1% formic acid in acetonitrile) in a gradient elution mode with a total run time of 100 min.
1.7 μm).The best peak resolution along with high sensitivity was achieved with an isocratic elution by a mobile phase comprising of acetonitrile: 10 mM ammonium acetate (60 40) at a flow-rate of 0.3 mL/min.
A mobile phase comprising of aqueous formic acid (0.1 %, v/v) (solvent system A) and acetonitrile (solvent system B) was employed with a gradient elution of 40 80 % B at 0 to 5 min, 80 85 % B at 5 to 10 min, 85 90 % B at 10 to 12 min, 90 95 % B at 12 15 min, 95%% B at 15 20 min.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak