Your English writing platform
Discover LudwigExact(6)
No mechanical tilt is used.
By applying this advanced method, the artificial nanohole can be as a calibration specimen to correct the mechanical tilt angles provided by a TEM goniometer.
In this study, a calibration specimen was fabricated by nanohole patterning using a focused ion beam in order to determine mechanical tilt angles.
We expect that the calibration specimen will effectively determine and correct the mechanical tilt angles in TEM goniometers leading to improvements in the ET technique.
Although monocrystalline diffraction patterns or Kikuchi diffraction patterns have been used to measure mechanical tilt angles in a previous report (Shaw and Hills 1981), the method is not applicable to all types of TEM specimens and currently manufactured transmission electron microscopes.
In order to improve the reliability of the electron tomography (ET) technique, which reveals three-dimensional information of nanostructured materials from a series of tilted two-dimensional images, it is essential that the mechanical tilt angle be accurately measured by the transmission electron microscopy (TEM) goniometer.
Similar(54)
In our concept, the "sun" is replaced by RF transmitter, mechanical tilting of a mirror is replaced by extremely low-power digital antenna impedance load modulation circuits, and the optical observer is replaced by a microwave receive system.
The combination of fast mechanical tilting and pore-filling of the porous silicon multilayer structure increases the tunable range to more than 200 nm or provides fine adjustment of working wavelength of the TOF.
In the simplest of terms, the idea of backscatter signaling is the modern radar equivalent of the 19th century optical "heliograph" wherein the sender used mechanical tilts of a mirror to modulate sunlight reflected to a distant receiver in patterns corresponding to Morse code.
This paper reports on the design and experimental evaluation of a high-resolution micro-electro-mechanical (MEM) tilt sensor based on resonant sensing principles.
The aim of this study was to compare the degree of LV mass regression measured by MRI 6 months after prospectively randomized valve implantation for two biological prostheses, stented and stentless, and for two mechanical valves, tilting disc and bileaflet.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com