Suggestions(5)
Exact(4)
It was shown that, for the same peak pressure amplitude, the resulting mechanical index was about 40% lower for MNC, lateral resolution was 10%to30%0% better and, what seems to be the most encouraging, the signal gain was up to eight times higher than pulse inversion.
The mechanical index was 0.08 0.11.
With the entering of CEUS status, acoustic output power, focus and gain were adjusted, and the mechanical index was set to 0.05 using a low mechanical index gray-scale continuous real-time ultrasound scanning technology.
The ultrasound instruments were GE Logiq 9 and GE Logiq E9 (GE Healthcare, Milwaukee, WI, USA); the probe frequency was 2.5 5.0 MHz; and the mechanical index was 0.12.
Similar(56)
The mechanical index is an important parameter that influences microbubble behavior in contrast ultrasound imaging.
However, reproducibility data for HR-pQCT-derived mechanical indices is not well-known.
Given the higher heart rate in rodents, cell mechanical indices were also examined in WT and APP/PS1 mouse cardiomyocytes paced at 5 Hz.
The center and halfwidth of the most important mechanical performance index are described as objective functions while the requirements of the other mechanical performance indices are described as constraint functions.
Furthermore, the constraint (g_{i} left( {{varvec{x}},{varvec{U}}} right) le B_{i} = [b_{i}^{L},b_{i}^{R} ])in Eq. (1) will degenerate as (g_{i} left( {varvec{x}} right) le b_{i}) when the mechanical performance index is independent of the interval parameters and the interval constant degenerates into a real number.
Mechanical index (MI) was deceased to 0.24, an experimental value verified by Professor Gao et al. Scanning setting was for optimal visualization, with the gain, scanning depth, field of view and time gain control (TGC), were determined throughout the study.
For all examinations, contrast-specific software (Coherent Contrast Imaging [CCI] and Contrast Pulse Sequencing [CPS], Siemens Acuson, USA; ECI, Siemens, Germany; Contrast Tuned Imaging [CnTI], Esaote, Italy) in continuous mode with very low mechanical index (0.01-0.1) was employed.
More suggestions(14)
mechanical behavior was
mechanical stimulation was
mechanical loading was
mechanical deformation was
mechanical device was
mechanical test was
mechanical force was
mechanical damage was
mechanical hyperalgesia was
mechanical load was
mechanical energy was
mechanical activation was
mechanical behaviour was
mechanical stirring was
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com