Sentence examples for measured phase shift from inspiring English sources

Exact(10)

The diffusivity of hydrogen in the oxide film is determined from the measured phase shift between the input hydrogen concentration and the hydrogen flux at the passivated side of the specimen.

The diffusivity of hydrogen in the oxide film and the concentration of hydrogen in the each layer were determined from the measured phase shift between the input hydrogen concentration and the hydrogen flux at the hydrogen exit side of the membrane specimen and from the measured steady-state hydrogen flux, respectively.

The black line shows the total phase shift while the blue lines correspond to the actually measured phase shift which is confined to within ±π range.

At low elevation levels, the bulk of measured phase shift values will lie just below the maximum possible value, Ψ max, but the statistical spread in the measured phase will shift some of the "true" phase values beyond Ψ max.

Furthermore, the corresponding potential variation needed to cause the measured phase shift under the assumption that the thickness is constant is indicated (case ii) and also the thickness variation needed to cause the phase shift under the assumption that the potential is constant (case i).

Two different populations of Cx43 molecules were thus resolved: one that exhibits FRET and another that does not, based on the measured phase shift (phase lifetime or τf).

Show more...

Similar(50)

Elevation selection is based on measuring phase shift Ψ between the echoes received by the main array and an auxiliary (interferometer) array.

The first pass was applied for the pre-measurement of a sample surface profile, and the second pass was performed in the phase image mode to measure phase shift distribution on the sample surface, which reflects distribution of the material characteristics.

EVSI represents a hybrid technique, using white light and measuring phase shifting.

To measure phase shifts induced by the combined signal at different phases, we simulated a PRC to the combined signal.

By measuring phase shifts of photons and their amplitude decay (compared to a reference signal), information on the optical properties of tissue is acquired and scattering and absorption can be distinguished.

Show more...

Ludwig, your English writing platform

Write better and faster with AI suggestions while staying true to your unique style.

Student

Used by millions of students, scientific researchers, professional translators and editors from all over the world!

MitStanfordHarvardAustralian Nationa UniversityNanyangOxford

Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak quote

Justyna Jupowicz-Kozak

CEO of Professional Science Editing for Scientists @ prosciediting.com

Get started for free

Unlock your writing potential with Ludwig

Letters

Most frequent sentences: