In the case of bulk materials, a maximum value of equivalent plastic strain and hardness is higher for the Berkovich indenter than for the Vickers.
The maximum values of equivalent strain, tensile strain, and compressive strain on the cortical bone surrounding implant increased 7.6%, 0.4%, and 5.9% in orthotropic model compared to isotropic model, while the average values of those increased 18.2%, 9.7%, and 13.3% in orthotropic model, respectively.
The maximum values of equivalent stress, tensile stress, and compressive stress on the cortical bone surrounding implant increased 8.1%, 10%, and 13.2% in orthotropic model compared to isotropic model, while the average values of those increased 15.3%, 28.5%, and 8% in orthotropic model, respectively.
However, the maximum value of the modal equivalent stiffness ratio depends on the length of the piezoelectric element.
According to the maximum value of the tire equivalent stiffness (γ = 0.75), If there is no vertical displacement of the bogie, the variation of the tire force is Delta F =Delta gamma cdot k_{1} cdot x = 13750,{text{N}}where x is the tire deformation under full load.
We have proposed a method based on mechanical impedance matching for enhancing the efficiency of the attached piezoelectric element and found that the width and thickness of the element were independent of the maximum value of the modal equivalent stiffness ratio, the parameter that determines the performance of passive vibration suppression under the ideal condition.
The maximum value for each group of equivalent reflections was assumed to best approximate the full intensity and was used for that reflection in the final data set.
The maximum values of the equivalent (von-Mises) and principal stresses for the 2D linear FEA are summarized in Table 5.
In the first 2 years of operation they have been exposed to a range of fluences up to a maximum value of about 4.5×1013 1 MeV neutron equivalent (neq) cm−2.
Importantly, the total amount (assuming eight placentas per individual) of placental P4 at its peak (d10.5) was almost equivalent to the maximum value of ovarian P4 on d14.5.
The maximum value of each score was 15 points, equivalent to 100%.