Sentence examples for maximum ion beam from inspiring English sources

Exact(2)

The NBI system, with the maximum ion beam power of 20 keV, 0.8 MW and pulse length of 10 ms, was designed for the auxiliary plasma heating and current drive source.

It is found that the maximum ion beam current is extracted at the optimum operating pressure at which the area of bias electrode exposed to ambient plasma is fully covered with the anode spot plasma whose size is dominantly determined by the operating pressure for given gas species.

Similar(58)

It is found that the optimum gap distance between the anode and the cathode is equal to 3.5 mm, where stable discharge current and maximum output ion beam current can be obtained.

Although the argon content increases with increasing Ar fraction in the ion beam to a maximum value of approximately 2%, it can be concluded that Ar yields a major stress contribution.

In the heating test, the mock-up was exposed to repetitive hydrogen ion beam irradiation with the maximum heat flux of 0.5 MW/m2.

On the other hand, when the height of the entering ion beam is 0.4 mm, the maximum intensity is 44, the corresponding peak position is 6.95, the half peak positions are -7.09722 and -6.70556, and the resolution is 6.95/ 7.09722-6.70556)=17.7.

A monoenergetic ion beam with a full-width/half-maximum (FWHM) of 5 mm is extracted from the accelerator system (synchrotron) and magnetically deflected to subsequently scan all planned iso-energetic slices roughly corresponding to the tumour's radiological depth.

A monoenergetic ion beam with a full-width/half-maximum (FWHM) of 5mm is extracted from the accelerator system (synchrotron) and magnetically deflected to subsequently scan all planned iso-energetic slices roughly corresponding to the tumour's radiological depth.

Finally, an optimum concentration of 20 40% [H2]/[H2+N2] ion beam composition was determined to obtain maximum nitrogen incorporation on the metal surface.

For (a) pristine and (b) irradiated film with a maximum magnetic field of 20 kOe applied parallel and perpendicular to ion beam direction.

The energy for each ion beam was set in order to reach a maximum penetration in ICRU tissue of 290 mm (equivalent to the therapeutic range of 430 MeV/amu carbon ions).

Show more...

Your English writing platform

Write better and faster with AI suggestions while staying true to your unique style.

Student

Used by millions of students, scientific researchers, professional translators and editors from all over the world!

MitStanfordHarvardAustralian Nationa UniversityNanyangOxford

Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak quote

Justyna Jupowicz-Kozak

CEO of Professional Science Editing for Scientists @ prosciediting.com

Get started for free

Unlock your writing potential with Ludwig

Letters

Most frequent sentences: