The following image sequence was used: a T1-weighted fat saturation, 3D spoiled gradient recall acquisition in the steady state; flip angle 55°; repetition time 58 msecs; echo time 12 msec; field of view 16 cm; 60 partitions; 512 × 512 matrix; acquisition time 11 min 56 s; one acquisition.
The following image sequence was used: a T1-weighted fat saturation three-dimensional gradient recall acquisition in the steady state; flip angle 55°; repetition time 58 ms; echo time 12 ms; field of view 16 cm; 60 partitions; 512 × 512 matrix; acquisition time 11 minutes 56 s; one acquisition.
The following image sequence was used: a T1-weighted fat saturation 3D gradient recall acquisition in the steady state; flip angle 55 degrees; repetition time 58 msecs; echo time 12 msec; field of view 16 cm; 60 partitions; 512 × 512 matrix; acquisition time 11 min 56 sec; one acquisition.
The following image sequence was used: a T1-weighted fat saturation three-dimensional gradient recall acquisition in the steady state; flip angle 55°; repetition time 58 ms; echo time 12 ms; field of view 16 cm; 60 partitions; 512 × 512 matrix; acquisition time 11 min 56 s; and one acquisition.
The following image sequences were used: (1) a T1-weighted fat saturation three-dimensional gradient recall acquisition in the steady state; flip angle 30 degrees; repetition time 31 msecs; echo time 6.71 msec; field of view 16 cm; 60 partitions; 512 × 512 matrix; acquisition time 11 minutes 56 sec; one acquisition.
Similar(55)
The following sequence and parameters were used: 1) T1-weighted fat saturation 3D gradient recall acquisition in the steady state (58 ms/12 ms/55°, repetition time/echo time/flip angle) with a 16 cm field of view, 60 partitions, 512 × 512 matrix and acquisition time 11 min 56 sec (one acquisition).
The following sequence and parameters were used: T1-weighted fat saturation 3D gradient recall acquisition in the steady state (58ms/12ms/55°, repetition time/echo time/flip angle) with a 16 cm field of view, 60 partitions, 512 × 512 matrix and acquisition time 11 min 56 s (one acquisition).
The following sequence and parameters were used: a T1-weighted fat suppressed 3D gradient recall acquisition in the steady state; flip angle 55 degrees; repetition time 58 msec; echo time 12 msec; field of view 16 cm; 60 partitions; 512 × 512 matrix; one acquisition time 11 min 56 sec.
The following parameters and sequences were applied: a T1-weighted fat suppressed 3D gradient recall acquisition in the steady state; flip angle 55 degrees; repetition time 58 msec; echo time 12 msec; field of view 16 cm; 60 partitions; 512 × 512 matrix; one acquisition time 11 minutes 56 seconds.
The following sequence and parameters were used: a T1-weighted fat-suppressed 3D gradient recall acquisition in the steady state; flip angle, 55 degrees; repetition time, 58 msec; echo time, 12 msec; field of view, 16 cm; 60 partitions; 512 × 192 matrix; one acquisition time, 11 min 56 sec.
The following sequence and parameters were used: a T1-weighted fat-suppressed 3D gradient recall acquisition in the steady state, flip angle 55 degrees, repetition time 58 ms, echo time 12 ms, field of view 16 cm, 60 partitions, 513 × 196 matrix, one acquisition time (11 min 56 s).
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak