Your English writing platform
Discover LudwigExact(2)
The magnitude of reflection and transmission coefficient obtained from numerical simulations are further validated with microwave free space measurements.
Interference of low-coherence light only occurs when the optical path length of reference and probe are matched within the coherence length of the light source, which means that the difference between the optical path of the reference and the probe light determines the depth in the sample at which the magnitude of reflection is registered.
Similar(58)
Bottom figure presents magnitude of reflections for capacitive (denoted by +) and galvanic (denoted by solid line) models of the coupled open ended coaxial waveguide resonators.
Consequently, presence of water alters the position and magnitude of reflections.
Therefore, we hypothesized that once reservoir pressure is taken into account, the magnitude of reflections would be minimal in the human aorta.
Indeed, although the NSCBC formulation of boundary conditions is often called "non-reflecting", the magnitude of the reflection coefficient approaches unity for low frequencies.
At interfaces of the complex ordinary relative dielectric permittivity ε ¯ r = ε r ′ − j ε r ″ a vertical incident electromagnetic wave is partially reflected according to: (1) r ¯ i = | r ¯ i | e j δ i = ε ¯ r i − ε ¯ r i + 1 ε ¯ r i + ε ¯ r i + 1 where r ¯ i is the magnitude of the reflection coefficient and δ i the reflection phase of the ith interface.
The principal target is the smooth muscle in distributing arteries, whose relaxation has little effect on peripheral resistance but causes substantial reduction in the magnitude of wave reflection.
The magnitude of a reflection path is not modeled to have a random characteristic, as it is treated as a controlled variable of the study.
In this paper, the magnitude of the reflection coefficients together with the respective end-corrections is experimentally determined for hot flow duct openings.
The measured magnitude of the reflection coefficient at the resonance frequency is used for reconstructing complex permittivity by proper de-embedding procedure based on 3D EM simulator CST Microwave Studio.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com