Your English writing platform
Discover LudwigSuggestions(3)
Exact(6)
A rotary evaporator (Büchi Re 120 model), an oven (Brand MEMMERT model), and a UV lamp (type CAMAG) have also been used.
The working conditions of AAS are listed below: Model: Perkin-Elmer AAS-700, Carrier Gas: Acetylene gas, Oxidant: Compressed air, Flame temperature: 2500 °C, Lamp: Hollow cathode lamp (HCL), Lamp type: Neon HCL, Gas flow: 2.5 L/min, Air flow: 5 L/min, and Gas pressure: 80 PSI.
Table 1 Instrumental parameters for FAAS of Zn and Fe analysis; GFAAS for Cd, Pb, and Ni analysis; and HGAAS for As analysis Instrumental parameters FAAS Zn/Fe GFAAS Cd/Pb/Ni HGAAS As Wavelength (nm) 213.9/248.3 228.8/283.3/232.0 193.7 Slit (nm) 0.7/0.2 0.7/0.7/0.2 0.7 Lamp type HCL/HCL HCL/EDL/HCL EDL Atomization temp.
The system comprised a high-energy pulsed ultraviolet-visible flash lamp (Type C, 190 nm spectral cut-off point) delivering a maximum of 1.27 J/cm.
Light from a tungsten-halogen lamp (type JC-24v/200 W, Kondo Philips, Tokyo, Japan) was collimated, and an interference filter with a transmission maximum at 700±10 nm (Olympus Optical, Tokyo, Japan) was used.
Check for lamp type supported by the ballast (likely T-8 type), and purchase lamp holders to fit lamps.
Similar(54)
Four lamp types were selected to create luminous conditions organized as a 2 × 2 factorial design, comprising two levels of CCT (i.e., 3500 and 5000 K) and lumen output (i.e., 2330 and ≈3000 lm).
An evaluation the combined luminance of all of the sources of light a single city is given in [31], a comprehensive review of the spectrum of different lamp types is given in [32], and discussion of the geometry of light pollution, and sky maps showing the sky radiance caused by single or multiple lamps is given in [33].
Decorative, round back, and flat back track heads are usually all offered with the above voltages and lamp types.
Another issue is that current LEDs generally provide only "directional light" rather than a 360-degree glow, meaning they are better suited to downward facing streetlights and ceiling lights than to many lamp-type settings.
Radiographic assessment was used blindly at end of the disease to evaluate the severity of OA radiography, using an X-ray collimator, model R-19, lamp-type 24 V, 90 W, on-load voltage 19 V (Ac max KVP 100 KVP min. inh, filt. 1 m, Japan).
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com