Exact(3)
For the 0.93 kPa case, the bubble shape detachment is described by Cassini oval while for 1.38 kPa it is a lenmiscate.
A 1.2 m thick clay barrier with a nominal overburden pressure of the order of 12.5 kPa was found to experience multiple cracking extending up to its full depth; whereas with overburden pressure of the order of 25 kPa, it was observed to have suppression of cracks.
For partial pressures greater than 20 kPa, it is necessary to employ a second-order polynomial algorithm: I0/I = 1 + k1(PO2) + k2(PO2) (3) where I0 is the fluorescence intensity recorded at zero oxygen tension, I is the intensity at oxygen tension P, k1 is the first coefficient and k2 is the second coefficient.
Similar(57)
The evaporation test indicates that the HCT is responsive and can measure negative pore-water pressure of up to 1300 kPa before it cavitates.
According to their work, the rate is approximately first-order with respect to naphthalene at pN < 0.5 kPa, but it is almost independent of the naphthalene concentration at pN > 1 kPa.
The flow standard can operate anywhere in the range 10 kPa
The raised CO2 concentration had no effect on perceived air quality or physiological responses except for end-tidal CO2 (ETCO2), which increased more (to 5.3 kPa) than it was in the reference condition (5.1 kPa).
In our experiment, we provided the decompression of about 30 kPa, and it produced an actuator displacement of about 800 μ m. Figure 7 shows variations in actuator displacement by different working fluids, including air, DI water, and glycerin.
The effect of chlorine partial pressure (pCl2) on the reaction rate was investigated for pCl2 of 9.21, 16.9, and 23.4 kPa, and it was identified that the chlorination rate is proportional to chlorine partial pressure on the order of (0.873).
For example, gripper with actuator No. 1 could lift up a 70 g target with a pressure of 20 kPa, but it required 40 and 50 kPa for grippers with actuators No. 3, and No. 4, respectively, to lift up the same target.
As the fatal wounding threshold value is around 40 psi and the peak pressure for DM-41 hand grenade is 268 kPa (~38,87 psi), it is definite that the value is between the limits of fatal wounding.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com