Your English writing platform
Discover LudwigSuggestions(1)
Exact(5)
Samples were injected by using a rheodyne injector fitted with a 20-μl fixed loop.
The GC was equipped with a cool-on-column injector fitted with a 10 cm length of 0.5 mm (i.d).
Samples were analysed on an Agilent 5975 Inert MSD coupled to a 7890A Gas Chromatograph fitted with a Zebron Amino acid ZB-AAA column (10 m × 0.25 mm I.D. Phenomenex, Cheshire, UK), Gestel MPS2 autosampler and split/splitless injector (fitted with quartz wool packed SGE FocusLiner).
The resulting solution (20 μL) was analyzed by Waters HPLC 515 having Rheodyne 7725i injector fitted with 20 μL loop and equipped with photodiode array (PDA) 2998 detector (Waters, USA) using a Waters column, C18 spherisorb 5.0 μm ODS2 4.6 mm × 250 mm column.
Automated 1-μL injections to the GC were made on a septum-equipped temperature programmable injector fitted with a high performance insert connected directly to a DB-5 HT capillary column (15 m × 0.25 mm i.d., 0.1 μm film thickness; J&W Scientific, Folsom, CA, USA) using helium as the carrier gas at a head pressure of 3 psi.
Similar(55)
Samples were injected through a Rheodyne manual injector valve fitted with 20 μL sample loop.
On-column injections were made using a septum-equipped temperature programmable injector (SPI) fitted with a high performance insert directly connected to a DB-5 HT capillary column (15 m × 0.25 mm i.d., 0.1 μm film thickness; J&W Scientific) with helium as carrier gas at a head pressure of 3 psi.
Michael Horn, the boss of VW in America, told a congressional hearing on Thursday that the hardware fix was "complex" and could involve a new fuel injector tank being fitted to cars.
The liquid chromatographic system Jasco LC900, consisting of a Jasco PU-980 Intelligent HPLC pump (Jasco, Japan) coupled with a Jasco UV-975 Intelligent UV/VIS detector and a Rheodyne injector (model 7725) fitted with a 20-μl sample loop, was employed for the study.
Samples were injected through a Rheodyne injector (Model 7010) fitted with 2 μL loop.
Liquid chromatography was performed using Waters 515 HPLC pump (Waters Corporation, Milford, MA. USA) equipped with a Rheodyne valve injector 7125i, which was fitted with a 50 μL sample loop (Rheodyne; Berodine, Berkeley, CA, USA).