Exact(7)
Incremental voltage adjustment tests at higher operating voltages were conducted on 2012 Jan 9 and the default HRC-S voltage settings were changed in mid-March, restoring performance to what it was circa 2002.
During the read process, the current linearly increases with the incremental voltage, in agreement with Ohmic Law.
Isoelectric focusing (IEF) was run following a stepwise incremental voltage program on an IPGphor Isoelectric Focusing System (GE Healthcare Life Sciences, Taipei, Taiwan).
Transient outward potassium currents and inward currents were triggered by applying a series of 10 mV incremental voltage pulses from −100 to 50 mV from a holding potential of −60 mV.
This dimension separates proteins in the mixture based on their isoelectric points (PI) following a stepwise incremental voltage program: 30 V for 16 h, 500 V for 1 h, 1 KV for 1 h, and 8 KV for 4 h, with a total power of 34 kV-h.
Eighty µg of protein was actively (50 V) loaded to IPG strips (11 cm, pH 5 8, Bio-Rad) at 20°C for 16 hr and then run through a stepwise incremental voltage program (250 V for 20 min (linear), 4000 V for 2 hr (linear), and 10000 V/hr (rapid)) by using Protean IEF system (Bio-Rad, USA).
Similar(53)
The voltage dependence of inactivation was determined by measuring current in response to pulses (20 ms) to −20 mV that had been preceded by 500-ms pulses applied in a series of 5-mV incremental voltages from −130 mV to −20 mV.
Input/output curves were obtained from the changing values in field decaying slopes upon delivery of incremental pulses of voltage (0 7 V, 1 V increments, 200 μs duration) and used to determine the strength of synaptic transmission.
Electrochemical skin conductance measurement is an active electrophysiologic method in which incremental low direct voltage is applied on the skin.
Time-domain simulation reveals that the proposed OHS-TSFL yields on-line, off-nominal model parameters, resulting in real-time incremental change in terminal voltage response profile.
Previous studies have analysed the effects of the DMs using incremental capacity and differential voltage (IC-DV) and electrochemical impedance spectroscopy (EIS).
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com