The heating beams designed were implemented with a clinical linear array imaging transducer connected to a research ultrasound platform.

We evaluated a new design for heating beams that can be implemented on a linear array imaging transducer and can provide improved heating area and efficiency as compared with previous implementations.

Since the US scanner cart could not be taken into the magnet room, the manufacturer provided a customised curvilinear 1 4 MHz US imaging transducer with an 8-metre long cable (CH4-1), thus allowing the cart to be located outside the MR room.

Figure 5 illustrates the appearance of noise from US imaging in MR images, showing T1-weighted axial image slices through the US imaging transducer and the cryogel sample, without (a-b) and with (c-d) aluminium shielding on the probe and cable.

As a result of the findings shown in Figures 10(a) and 11, it was decided that, as a compromise between the practicality of mounting the US imaging transducer and the ability to acquire images with a variety of MR sequences without causing prohibitive loss of signal or geometric distortion, a transducer-sample separation of 4 7 cm should be used.

Transthoracic echocardiography was performed using a Toshiba ultrasonic image analyzing system (Nemio-XG) equipped with 7.5 MHz imaging transducer.

Show more...

Similar(32)

We report a method of fabricating backing blocks for ultrasonic imaging transducers, using alumina/epoxy composites.

They could also be helpful in optimizing the design of imaging transducers employed in ultrasound systems designed for coded excitation.

Energy losses (or energy dissipation) in ferroelectrics are one of the most critical issues for high power devices, such as therapeutic ultrasonic transducers, large displacement actuators, SONAR projectors, and high frequency medical imaging transducers.

Current TSI systems use separate heating and imaging transducers, which require physical alignment of the heating and imaging beams and result in a bulky setup that limits in vivo operation.

Spherically focused, high frequency (30 50 MHz) ultrasonic imaging transducers are fabricated using poly vinylidene) difluoride (PVDF) film and a membrane deflection technique that is compatible with CMOS microelectronics fabrication.

Show more...

Ludwig, your English writing platform

Write better and faster with AI suggestions while staying true to your unique style.

Student

Used by millions of students, scientific researchers, professional translators and editors from all over the world!

MitStanfordHarvardAustralian Nationa UniversityNanyangOxford

Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak quote

Justyna Jupowicz-Kozak

CEO of Professional Science Editing for Scientists @ prosciediting.com

Get started for free

Unlock your writing potential with Ludwig

Letters

Most frequent sentences: