Your English writing platform
Discover LudwigSuggestions(2)
Exact(3)
The non-echoplanar technique can generate image slices without air-bone susceptibility artefacts and distortion, as thin as 2 3 mm producing a high resolution matrix, which is essential for the detection of tiny cholesteatoma pearls (Fig. 3).
Non-echoplanar DWI is capable of acquiring thin slices (as thin as 2 mm) and generating a high resolution matrix, and hence can detect cholesteatoma as small as 2 mm [3, 4, 5].
More recently, it was shown that 2D radial MR imaging could overcome the short dissolved-phase T2* and directly image 129Xe in the pulmonary tissues of rats [21] at relatively high resolution (matrix = 64×64; pixel size = 1.25×1.25 mm2).
Similar(57)
The identity of Hep-1 in mouse serum was confirmed by high resolution Matrix-Assisted Laser Desorption Ionization - Fourier transform ion cyclotron resonance (MALDI-FTICR) MS and that of Hep-2 by Q-STARXL MS/MS (see Supporting information Materials and Methods S1 for details).
Use of a short repetition time (≈4 ms), and echo time (≈1.6 ms) combined with interpolation algorithms, allows higher resolution matrices and a thinner effective slice thickness with minimal time penalties.
This paper considers the background, approaches and achievements in design of the silicon-based LEDs and high-resolution matrix displays.
For any sequence, artefacts can be minimised by using a small field of view, high-resolution matrix, and thin sections (Fig. 1).
Conventional strategies to optimize the image quality close to metal implants are a high bandwidth per voxel, 3D spatial encoding, a high-resolution matrix, and a multiecho spin-echo (SE) sequence or turbo/fast SE sequence [23].
Separations of heteroduplexes from homoduplexes were achieved with the Reveal high-resolution matrix (SpectruMedix MREV-HR-225-001v3).
High-resolution matrix-assisted laser desorption/ionization time-of-flight (MALDI-ToF) mass spectrometry (MS) analysis showed that ProcAt.1 had been dehydrated up to three times.
Also, since the CMT-BCS algorithm is known to be less sensitive to the dictionary coherence, it is a good choice for the underlying problem where it is desirable to have a high resolution measurement matrix.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com