Exact(5)
The solution is compared with existing experiments which measured natural circulation flow through the annular gap slice model.
Contour width, air gap, slice height, raster width, raster angle and angle of orientation are treated as process parameters.
For the resting state scan, the parameters were: 210 time points, matrix = 64×64, 20 axial slices without gap, slice thickness = 4 mm, TR/TE = 2000 ms/30 ms, flip angle = 90°, FOV = 192 cm.
44 axial slices were recorded in tilted angle (AC-PC + 30°; interleaved acquisition, no gap, slice thickness 3 mm, and in-plane resolution 3 × 3 mm) to reduce susceptibility artifacts in inferior brain areas [ 26].
Single-shot echo planar imaging DTI was acquired using a twice refocused spin echo sequence (Reese et al., 2003) with the following sequence parameters: TR/TE = 8400/82 ms; b = 700 s/mm; NEX = 1; 10 T2 images acquired with b = 0; 72 diffusion directions; 128 × 128 matrix; 2 × 2 mm in-plane resolution; 64 axial oblique (AC-PC) slices; 2 mm (0 mm gap) slice thickness; scan duration 12′44".
Similar(54)
Two sets of functional data were acquired using a whole brain echo-planar pulse sequence (repetition time = 2570 ms, echo time = 50 ms, flip angle = 90°, field of view = 192 × 192, slice thickness = 3 mm, 1 mm interslice gap, slices = 30, matrix size = 64 × 64, voxel size = 3 × 3 × 4 mm).
Functional data were acquired using whole brain echo-planar pulse sequence (repetition time =2570 ms, echo time = 50 ms, flip angle = 90°, field of view = 192 × 192, slice thickness = 3 mm, 1 mm interslice gap, slices = 30, matrix size = 64 × 64, voxel size = 3 × 3 ×4 mm).
32*3 mm slices (1 mm inter-slice gap, descending slice order) were acquired in 2 seconds for each image (in-plane resolution 3×3 mm).
The following imaging parameters were used: STIR-images: echo time (TE) 18 ms, repetition time (TR) 1100 ms, gap 0.0, slice thickness 3.0 mm, FOV 200 × 200 mm, matrix 256 × 160.
To fill this gap, MBO slice cultures were generated and treated with or without histamine as described in Section 2. To further verify the successful penetrance of histamine, 2 mm slices were sectioned and grouped at different depths from the slice surface (proximal, 0 350 μm; middle, 350 700 μm; and distal, 700 1050 μm from the slice surface).
To be extra safe hold them like this - make a bridge shape with your fingers, put the knife in the gap, and slice.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com