With the assumption of oxygen mass balance and a cylindrical vessel, the model provides a relationship between oxygen flow, saturation, and pressure.
Similar(59)
The simulations with different source pressures, muscle volumes, and flow saturations in the pneumatic circuit were calculated to analyze the factors of muscle performance.
Much work on fluid flow and saturation has focused on traditional pressure-gradient driven flow represented by viscous multi-phase Darcy flow.
The obtained mass transfer rate model gives smaller values for the predicted mass transfer rate but shows a comparable dependence on water flow and saturation as in earlier published one-dimensional column experiments with identical characteristics for porous medium, DNAPL and surfactant.
As the gas cylinder connects six branch pipes for the muscles from one main pipe simultaneously, the gas flow at saturation, and the gas flow in the main pipe can be obtained through the continuity equation: Q = pi r^{2} v, (9 where Q Main pipe flow rate, r Pipe radius, v Flow velocity in the pipe.
In the above formulas, ρ, v, S, q, μ, and k r represent density, flow velocity, saturation, production rate, viscosity, and relative permeability, respectively; k is the absolute permeability; p is the formation pressure; (phi) is porosity; and x is the flow direction.
The relative affinity of each anti-CAIX scFvFc to native CAIX molecules was determined by staining of the 293T-CAIX cells using serial dilutions of each scFvFc in flow cytometric saturation binding studies (Figure 2 C&D).
Overall, the NIR spectrum can provide information on tissue blood flow, oxygen saturation and consumption, and compositions.
Such scattered light may include information about dynamical processes like blood flow, hemoglobin saturation, and pulse from inside the finger.
Capillary blood flow, O2 saturation of Hb (SO2Hb) and the relative concentration of Hb (rHb) were assessed at a 2 mm skin depth.
In the real world, the redundancy of flow and saturation channels would have allowed a clinically useful interpretation even if there were valid data from only one channel.