This instrument achieves mass resolving power of up to ∼27,000 (M/ΔM) and can analyze diverse gases and semi-volatile compounds using a conventional dual inlet and/or a carrier gas.
DI: analyses on a CO2 aliquot from the radiocarbon preparation, performed using a Dual Inlet IsoPrime stable isotope mass spectrometer.
The samples were analyzed for δD (hydrogen isotope-2H) and δ 18O (oxygen isotope) stable isotopes using continuous flow isotope ratio mass spectrometer and dual inlet isotope ratio mass spectrometer available at the National Institute of Hydrology (NIH), Roorkee.
The analyses on a CO2 aliquot from the radiocarbon preparation were performed using a Dual Inlet IsoPrime stable isotope mass spectrometer at the AMS 14 Dating Centre at Aarhus University.
The isotopic abundance of the purified SF6 was analyzed on a Finnigan MAT 253 dual inlet mass spectrometer at m/e-values of 127, 128, 129, and 131 (33SF5+, 34SF5+, 34SF5+, and 36SF5+).
The natural mass fractionation, δ13C, was measured with a VG OPTIMA dual inlet mass spectrometer.
Similar(47)
Five modifications on the baseline T-separator with horizontal inlet are explored using both R134a and R410A as working fluids: inlet inclination angle, dual-inlet as pre-separation, inlet tube diameter, cross-sectional shape and location with respect to the vertical tube.
It is widely recognised that a significant limitation to the ultimate precision of carbon stable isotope ratio measurements, as obtained from dual-inlet mass spectrometric measurements of CO2 isotopologue ion abundances at m/z 44, 45, and 46, is the correction for interference from 17O-bearing molecular ions.
The measurements were performed in a dual-inlet mode using a DeltaPlus mass spectrometer with a peripheral H/Device.
A total of 32 stable oxygen (δ18O) and carbon (δ13C) isotopes were analysed from powder dolomite and calcite samples using a Thermo Scientific Kiel IV automated carbonate device connected to a Thermo Scientific MAT253 dual-inlet isotope ratio mass spectrometer in the Analytical Laboratory for Paleoclimate Studies (ALPS) at the Jackson School of Geosciences, University of Texas at Austin.
These strategies are: single window opening, same side dual-opening, inlet and stack as well as ceiling-based natural ventilation (CBNV), a new concept.
More suggestions(1)
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com