Your English writing platform
Discover LudwigSimilar(60)
A fundamental advance in the development and application of cell- and tissue-based biosensors would be the ability to achieve air-dry stabilization of mammalian (especially human) cells with subsequent recovery following rehydration.
Drying, stabilization and carbonization processes were performed sequentially, and repeated to increase the pitch content.
Under controlled plastic-covered sun drying bed stabilization results (Tables 3, 4) and the BCC values (Table 6), the LWSC biosolids qualify as restricted land application use equivalent to Class C on the Australian scale.
The slides were then washed at room temperature in 20X SSPE and 20% N-laurylsarcosine and dried with the Stabilization and Drying Solution (Agilent Technologies).
After hybridization, slide arrays were subjected to two successive washes (wash solution 1: 6× SSPE, 0.005% N-Lauroylsarcosine, and wash solution 2: 0.06× SSPE, 0.005% N-Lauroylsarcosine) and dried with the Stabilization and Drying Solution (Agilent).
After hybridization, microarrays were washed for 1 min at room temperature with GE Wash Buffer 1 (Agilent) and 1 min with 37 °C GE Wash buffer 2 (Agilent), then dried using Agilent stabilization and drying solution.
Two requirements for cell survival during freeze-drying are stabilization of the membrane during the drying process [11] and the ability to form a stable vitrified matrix of cells in the unfrozen fraction.
Curing (180 days) was developed throughout several ordered steps: salting, stabilization, drying and ripening.
Oxidizing, dry conditions favor the stabilization of secondary phases, while promoting oxidative breakdown of the primary sulfides.
Radical scavenging by a citrus LEA protein [ 29] and the stabilization of dry sugar glasses by LEA proteins from Typha latifolia [ 55] and soybean [ 56] have also been reported.
After hybridization, microarrays were washed with GE Wash Buffer 1 (Agilent) at room temperature for 1 min, GE Wash buffer 2 (Agilent) at 37 °C for 1 min, acetonitrile for 10 s and Agilent's stabilization and drying solution for 30 s and, then air dried.
More suggestions(1)
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com