Exact(2)
This is somewhat smaller than the ±3.0 nm standard deviation of the half helical pitches of actin filament paracrystals, and the difference should derive from small structural fluctuations in the paracrystals and/or measurement error from various other sources.
Furthermore, assuming normal distributions of the true half helical pitches and measurement errors, the true standard deviation of the half helical pitches of control filaments was calculated to be 3.1 nm or larger, by subtracting the variance of the actin paracrystals from that of control filaments.
Similar(58)
It has 6 parameters namely height of the peak (H), location of the peak summit, the standard deviation of the first half of the peak (σ1), that of the second half of the peak (σ2), the fraction of Lorentz function used in the first half of the peak (β1) and that of the Lorentz function used in the second half of the peak (β2).
When this function is used to model peaks in mass spectra, the intensity values of a peak can be modelled as a function of mass values (m) as follows: L m = H × 1 1 + m - α σ 2. Bi-Gaussian function has 4 parameters namely height of the peak (H), location of the peak summit, standard deviation of the first half of the peak (σ1) and that of the second half of the peak (σ2).
Error bars show the standard deviation of the relative half-lives measured in the different experiments.
For the 3-D modeling, we approximated the standard deviation of the TF as half of the TF errors, which are listed in Ogawa (1987a).
The standard deviation of the distribution of half helical pitches of the fully cofilin-decorated filaments was 3.8 nm, and subtracting the maximum possible measurement error yielded a standard deviation of 2.3 nm or larger.
Since a clear estimation of the deviation of the results of half-space-based methods from those of the FE method is provided, the applicability of half-space-based methods in mechanical engineering can be much better understood.
For the 200 subjects with complete observations over 15 years the mean rate of decline was similar to that observed over five year periods, but the standard deviation of the rates of decline was half that of the 5-year estimates, reflecting greater accuracy from multiple measurements.
However, Buch [ 6] reported a worse range of motion in the upper and lower ankle joint after performing a percutaneus wire osteosynthesis in 100 calcaneal fractures with a varus or valgus deviation of the back foot occurring in half of the cases.
In order to remain in the stimulant-only condition, the child had to obtain a score within one-half standard deviation of the mean for a normative sample on the main outcome measure of ODD behaviors (including aggression; NCBRF D-Total) and a CGI Improvement rating of "Very much improved".
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com