Your English writing platform
Discover LudwigSuggestions(1)
Exact(1)
Furthermore, different light sources like NIR (near infrared probes) or dual wavelength light sources could be used in the future to increase penetration depth of scanning light [ 12, 13].
Similar(59)
The scanned elements were Cu, Zn, Sn, Se, and O; the scanning rate was approximately 100 nm/min, and the signal collection rate was 2.5 times per minute, so the accuracy of the measured depth of each scanned element was approximately 40 nm.
SD-OCT and TD-OCT systems typically use a point of illumination and produce a one dimensional depth scan (A-scan) of the backscattered light signal as a function of depth below a single point on the tissue surface.
The depth of the scan was adjusted and the transmit focus zone set at the optimal level to show the best possible image of the far wall of the CCA.
Contrast in OCT imaging can be augmented by measurement of the attenuation coefficient, which has been demonstrated as a means for identifying lesions in cancer imaging [ 23– 26] and plaque components in atherosclerotic arteries [ 27, 28]. Figure 1 presents a typical OCT average depth scan (A-scan) of a homogeneous sample for which the optical properties are to be extracted.
With this sensor NMR depth profiles were collected, these profiles encode the amplitude of the 1H NMR signal as a function of the depth scanned.
Fully automatic conversion is contained; Foreground detection and edge information help unify the depth value on the object; Superpixel algorithm clusters pixels with close information; Six kinds of initial gradient hypothesis for initial depth map; Four kinds of scanning modes to fix the depth map; Through a Hough transform, we only extract one-line information to get the slope of the line.
OCT imaging probes require the incorporation of a lateral scanning mechanism to generate cross-sectional images (termed B-scans) by acquiring a sequence of individual depth scans (termed A-scans) from different lateral positions within the imaging target.
Quantitative analysis of architectures extracted from captopril osmotic pumps drilled by a range of operating parameters indicated that laser power correlated with the cross section area, volume, surface area and depth of the orifices, while scanning speed of laser beam showed inverse relationships with the above structure characters.
Divetia et al. [ 7] used a 1 mm liquid-filled polymer lens for endoscopic OCT applications that dynamically provided scanning depth of field by changing the hydraulic pressure within the lens, which enabled dynamic control of the focal depth without the need for articulated parts.
Doppler OCT (D-OCT) [ 11] and Phase Contrast (PC -OCT [ 12] are motion sensitive methods for vessel visualization, since these methods collect more than one dePC -OCTn of the same retinal loci and analyze Doppler phase shifts between depth scans at different depths.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com