Suggestions(1)
Exact(4)
Prior research, however, has reported that some RBS-B connection specimens failed by connection fracture prior to reaching the 2% radian rotation.
A method is proposed for detecting the building-wide level of connection fracture damage, based on observing high-frequency, fracture-induced transient dynamic responses in strong motion accelerograms.
Finally, we present a procedure to design RBS-B connections without connection fracture for new building systems, and to estimate the probability of RBS-B connections to develop rotation capacities larger than 2% radian for existing IMF systems.
This leads to the suggestion that in order to avoid connection fracture during cooling, it may be possible to reduce the limiting temperature of the connected beam by a small value (<50 °C) from the limiting temperature calculated without considering any axial restraints in the beam.
Similar(56)
Structural dynamics theory predicts and scale model experiments have demonstrated that sudden, large changes in structure properties caused by moment connection fractures will cause transient dynamic response.
The simplified method can reduce the analysis time enormously and allows design engineers to assess the possibility of connection fractures, or determine approximate values of toughness and defect size requirements for given peak stress and strain level.
From the analyses results, it can be seen that the simplified method can enormously reduce the analysis time and allows design engineers to assess the possibility of connection fractures, or determine approximate values of toughness and defect size requirements for given peak stress levels.
Fracture and debonding of shear connection Although fracture of shear connection and debonding is unlikely to occur, allowance for such considerations may be necessary (Teng et al. 2001; Oehlers et al. 1994).
Her early onset Alzheimer's had been diagnosed four years earlier, but I never expected our connection to fracture so soon.
The close spatial connection to fracture zones provides a basis to avoid bedrock affected by this type of alteration and, thereby, reduce the negative mechanical and hydrogeological aspects for a deep geological repository.
During the well publicised Cardington structural fire research programme, parts of some connections suffered fracture during cooling.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com