Your English writing platform
Discover LudwigExact(1)
Differences in aerosol generation and transport efficiencies between solution nebulization and LA were assessed by ablating in-house hair material with known analyte element concentrations.
Similar(59)
The resulting method detection limit of 3 pg g−1 (3σ) provided a 15-fold improvement over that obtained using direct solution nebulization, and is comparable to that for conventional chemical hydride generation (HG -ICPMS.
Bartkus et al. and Arriaza et al. both used whole in-house hair standards, quantified for Pb and As by conventional solution nebulization and hydride generation ICP-MS, for calibration of LA-ICP-MS measurements [ 68, 69].
Reference concentrations were obtained from conventional solution nebulization ICP-MS and C was used as internal standard for LA-ICP-MS.
Dressler et al. achieve agreement within analytical error [ 66], and the results of Rodushkin and Axelsson also showed a good correlation of LA-ICP-MS and solution nebulization ICP-MS results; generally, LA-ICP-MS results are within 30%% of solution nebulization ICP-MS results.
Phung et al. performed LA-ICP-MS analysis in holes left by micro-drill sampling for solution nebulization ICP-MS analysis and subsequently compared results from both procedures involving two different LA-ICP-MS facilities [ 52].
Sinclair et al. converted LA-ICP-MS line scans on corals into average concentrations for five elements and compared these to results from solution nebulization ICP-MS of a digest of the same sample [ 26].
Dressler et al., Sela et al., and Rodushkin and Axelsson all compare their LA-ICP-MS results for human hair and nail samples to results from conventional solution nebulization ICP-MS [ 66, 67, 70].
For the analysis of hair and nail, detection limits in LA-ICP-MS range from picograms per gram to nanograms per gram and are quoted as only marginally nferior to conventional solution nebulization ICP-MS as a result of sample dilution after digestion for the latter approach.
The in-house hair standard material was prepared by immersion of hair strands in a multi-solution, subsequent drying, and digestion of the material thus obtained for the determination of reference concentrations via conventional solution nebulization ICP-MS.
Reference concentrations were obtained from conventional solution nebulization ICP-MS after sample digestion.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com