Exact(2)
A macro modeling approach was adopted and equivalent material parameters were obtained from in-situ tests and the calibration of the FE model was used as the input of the model.
Various diffusivity processes are investigated: prediction of moisture diffusion path and local moisture concentration inside a material samples during a sorption test, comparing total mass uptake for real microstructure and equivalent material models, sorption behavior of cracked samples with different crack volume fraction, hygro-thermal resin swelling simulation.
Similar(58)
But due to lots of problems existed in the quality and technique control and other aspects of SiC and equivalent materials currently, the process is just remained at the sample and product phase of small capacity.
74, 741 753] from several points of view: (i) the result holds for anisotropic phases with spherical or circular ellipsoid of inertia; (ii) the displacement boundary conditions considered in the homogenization procedure is independent of the characteristics of the material; (iii) a perfect energy match is found between heterogeneous and equivalent materials (instead of an optimal bound).
Detector efficiency was calculated for point sources, in air and tissue equivalent material.
If the contents of a trial pack are destroyed, or unfit for use, the person should not be randomised a second time and the equivalent material should be obtained from the usual hospital supplies.
Information about the anatomical characteristics of the human neck has been collected and analysed, and tissue equivalent materials were selected for mimicking soft, cartilaginous and bone tissues.
The phantom referenced the geometrical size of Chinese adult heads and used tissue equivalent material with similar radiation absorption and scattering to human tissues.
Zachsic, Salt Lake City And this … I will keep saying this til something changes, however long it takes: Get these boys out of plastic and into leather or some equivalent material, for both pads and helmets.
The 20-cm cylinder phantom is also analyzed with and without the tissue equivalent material.
Cells were placed on 5 cm of water equivalent material and another 10 cm on top to allow for full scattering and back scattering conditions.
Write better and faster with AI suggestions while staying true to your unique style.
Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak
CEO of Professional Science Editing for Scientists @ prosciediting.com