The phrase "air termination" is correct and usable in written English.
It is typically used in the context of electrical engineering or lightning protection systems to refer to the point where a lightning protection system connects to the air.
Example: "The air termination must be installed at the highest point of the structure to ensure effective lightning protection."
Alternatives: "lightning rod" or "air terminal".
Exact(2)
While the efficiency of the air termination system is not determined by the radius of the sphere, the rolling sphere method is now the best design procedure for air termination systems.
An important consideration in the design of any air termination system is the maximum distance at which the terminations can be placed from the "vulnerable points" on structures, i.e., typically those points that create the highest degree of electric field intensification.
Similar(58)
Secondly, account is taken of the material of construction of the building on which the air terminations are installed.
Eleven air terminations were tested against the Franklin rod and the results captured with a high speed gated camera.
Firstly, the height range of the air terminations has been extended by a factor of 4 with a series of additional calculations.
A test setup with a 5 m air gap has been designed and manufactured with the aim of producing upward leaders from competing air terminations, thus simulating natural lightning conditions more closely.
All of the results are compared and some quantitative guidelines are provided for the maximum distance at which air terminations should be installed from the vulnerable points of structures.
According to the comparison between the above systems, a proposed air-termination system is developed and experimentally examined.
In this paper, air-termination systems for wind turbine blades reported in IEC-61400-24 stareard arevaluatedexperimentallylly.
This paper introduces application of genetic algorithm (GA) in designing air-termination system of the high-voltage (HV) open-air substation external lightning protection system (LPS).
The complex air-termination system, as a part of the external LPS of HV substation, is known to be cumbersome to design using traditional techniques, where optimisation is often relegated to the trial-and-error approach.