To ensure proper matching between the collector/evaporator load and compressor capacity, a variable speed compressor was used.
Rapid cycling the compressor of an air conditioning or refrigeration system can be used to modulate capacity, thus offering an alternative to a variable speed compressor.
This paper presents an autoregressive moving-average model with exogenous inputs (autoregressive moving-averagentroller for a household refrigeration systemodelt uses a variable speed compressor.
Even larger improvements are possible in case a variable speed compressor is utilized to match the performance of the conventional DX-system.
The identified model of the AAC system can be used for further implementation in a model based intelligent control of an AAC system equipped with a variable speed compressor.
In this paper, a nonlinear autoregressive neural network with exogenous inputs (NARX) is proposed to model the dynamic behaviour of an automotive air conditioning (AAC) system equipped with a variable speed compressor.
Similar(52)
Many models were conceived to optimize a specific element of the system: replacement of refrigerant fluid by a new one [13], installation of a variable-speed compressor [8] or development of a new thermal insulation for the enclosure [14].
This paper presents the results of an experimental analysis which compares in terms of energetic performances the refrigeration capacity control obtained by means of a variable-speed compressor with the on/off control deriving from a classical thermostatic device.
A purpose-built testing apparatus comprised of a variable-speed compressor and a pulse-width modulated expansion valve was used to collect data for the system identification and model validation exercises.
A purpose-built testing apparatus comprised of a variable-speed compressor and a pulse-width modulated expansion valve was used to collect data for the system identification, and model and controller validation exercises.
In a direct expansion (DX) air conditioning (A/C) system having a variable-speed compressor and supply fan, the degree of refrigerant superheat regulated by a built-in conventional proportional integral derivative (PID) controller would experience fluctuation, after the speeds of both compressor and supply fan were regulated by a capacity controller.