Sentence examples for a sharp current from inspiring English sources

Exact(2)

For a pressure of 2.7 Pa a sharp current peak occurs upon application of voltage, while for a pressure of 133 Pa a rectangular current pulse shape is formed, similar to the shape of the applied voltage pulse.

Figure 8b shows the resistance value after the different pulse amplitudes from −2 to −5 V were applied to the devices; for the abrupt reset switching, a switching response was not registered until −4.5 V and a sharp current drop was observed at −5 V.

Similar(57)

A second event shown in Figure 1 d displayed an unusual time structure in that, after an initial sharp current blockage of short duration, the ionic current temporarily returns to the open pore value before a blockade of similar duration.

As shown in the figure, there is a sharp initial current drop, followed by a very slow decay.

In the case of trapping-type RRAM, no sharp current jump has been observed during the set process, but sharp current jumps have been commonly observed for filamentary-type RRAM.

However, a close look at recorded curves enlarged in the inset of Figure 2 reveal the sharp current transients in the case of the acidified polysulphide solution.

Observed i-t response is usually combination of two components: capacitative current related to the charging the double-layer and Faradaic current related to the electron transfer reaction e.g. sharp current transients due to Faradaic charge transfer while the NPs is in a contact with Hg electrode.

The Ni/Si3N4/p + -Si RRAM device then showed a forming-less process, indicating that the forming voltage is within the distribution range of the set voltage; notably, with the 5-mA CC, sharp current drops were observed for all of the reset switching during 100 consecutive DC voltage sweeps.

However, such considerations always remained subservient to climatic influences such as "sharp currents of air" or "great vicissitudes of temperature".

When 3 M methanol was introduced into the O2-saturated alkaline electrolyte at 200 s, no noticeable degradation of current was observed for the NC-6 electrode, as shown in Fig. 8a, whereas a sharp drop in current occurred for the Pt/C electrode.

"This is a sharp departure from current practice," he said.

Show more...

Ludwig, your English writing platform

Write better and faster with AI suggestions while staying true to your unique style.

Student

Used by millions of students, scientific researchers, professional translators and editors from all over the world!

MitStanfordHarvardAustralian Nationa UniversityNanyangOxford

Since I tried Ludwig back in 2017, I have been constantly using it in both editing and translation. Ever since, I suggest it to my translators at ProSciEditing.

Justyna Jupowicz-Kozak quote

Justyna Jupowicz-Kozak

CEO of Professional Science Editing for Scientists @ prosciediting.com

Get started for free

Unlock your writing potential with Ludwig

Letters

Most frequent sentences: